The Utility of Early Warning Score in Adults Presenting With Sepsis in the Emergency Department of a Low Resource Setting



Abstract

Background

Sepsis is a condition with high mortality and morbidity. Delay in early recognition and prompt management results in higher mortality. There are many clinical scores to identify early sepsis; however, Early Warning Score (EWS) has clinical/physiological parameters that are easy to apply in the ED for timely diagnosis and management. In the present study, we collected information regarding the utilization of EWS in timely identifying the sick patients at triage of a tertiary care center.

Methods

This study was a descriptive cross-sectional investigation conducted in the ED of Aga Khan University Hospital in Karachi, the largest metropolitan city in Pakistan. A total of 240 participants were selected by non-probability convenient sampling after fulfilling the inclusion criteria. Data collected included EWS criteria, demography, length of hospital stay, patient disposition (ward, intensive care or high dependency area), and differentials like sepsis, severe sepsis or septic shock.

Results

A total of 240 patients were enrolled, out of which 139 (57.9%) patients were male, and 101 (42.1%) were female with a mean age of 52.7 ± 15.3 years (range: 18 to 80 years). In this study, the length of stay (LOS) was 2.2 ± 1.1 (range: one to six days), and there was an EWS of 8.2 ± 2.6 (4-15). There were 143 patients in the elderly age group > 50 years (59.6%); however, most elderly presented with sepsis among both age groups. The least affected age group was aged 16 to 30 years, with 23 (9.6%) cases. An EWS >7 is best to detect cases with sepsis or severe sepsis with a sensitivity of 98.5% (95% CI: 92.13 to 99.92) and specificity of 89.57% (95% CI: 82.64 to 93.93). Similarly, the EWS for severe sepsis or septic shock was >9 with a sensitivity of 86.76% (95% CI: 76.72 to 92.88) and specificity of 88.24% (95% CI: 78.47 to 93.92).

Conclusions

This study revealed that the sensitivity and specificity of EWS for the detection of sepsis, severe sepsis and septic shock was found to be high; hence, it could be a valuable and readily useable system for early diagnosis and proper management of sepsis, severe sepsis, and septic shock.

Introduction

Observational studies suggest that the clinical signs of deterioration may present as early as 24 hours before presentation to the hospital as a serious clinical event [1]. Sepsis is a condition with high mortality and morbidity [2,3]. Local sepsis data from urban settings demonstrate a mortality rate of 23% [4]. Sepsis tends to progress very rapidly, and a delay in early recognition and treatment can result in higher mortality [5]. More rapid administration of antibiotics also reduces overall mortality from septic shock, as recommended by the Surviving Sepsis Campaign [4]. However, since the introduction of early goal-directed therapy, mortality significantly reduces to 7% to 16% in certain hospitals [6].

There are multiple criteria for sepsis identification in clinical use, with most using both clinical and laboratory parameters that may not be useful in early identification [7-14]. Early Warning Score (EWS) is a tool based on clinical and physiological criteria [15]. Hence, it is easy to use and track sepsis within the busy ED. The score has shown promise in early detection and management of septic patients, resulting in good outcomes.

EWS, based on previous similar scoring systems, is comprised of seven physiological parameters, each of which is assigned a value between 0 and 3 along with an additional parameter for supplemental oxygen, which scores zero or two [12-14]. The score for each of these seven parameters is summed to calculate the EWS, which may range between 0 and 15: the higher the score, the greater the deviation from normality [15].

EWS is a good modality to identify early sepsis at triage as it contains basic parameters which may be measured easily in a short time even in a remote setting with just a basic vital monitor and a junior nurse. Similar scores like national early warning score (NEWS) or NEWS-2 include Carbon dioxide (Co2) which is difficult to measure at triage. In our setting, emergency severity index (ESI) v 4.0 is used as a standard of care and all basic parameters already embedded in our system. ESI is a good tool to identify sick patient; however, ESI III is the most grey area where a larger number of patients fall who may either be more sick or not at all, hence another handy, easy to use system is the need to differential and identify septic patient at triage with more precision.

In this study, we aim to assess whether EWS may identify sepsis, severe sepsis, and septic shock very early at ED presentation, which may help in the early identification of sick patients with timely management of their condition, hence reducing morbidity and mortality.

Materials & Methods

This was a single-center cross-sectional study, conducted at the ED of Aga Khan University Hospital in Karachi, Pakistan. The duration of the study was approximately six months between May 11, 2016 and November 10, 2016.

The participants were selected through a nonprobability consecutive sampling technique. The prevalence of sepsis in the intensive care units of Pakistan is reported to be 7% [4]. Using the World Health Organization sample size calculator, with a 95% CI, and 3% margin of error, the estimated sample size was calculated to be 240.

Patients aged 18 years and older of either sex attending the critical area of ED with a temperature of either > 38.3°C or < 36.0°C, a pulse > 90 beats per minute, a respiratory rate > 20 breaths per minute, and an oxygen saturation of < 94% along with presumed or confirmed infection (confirmed cases as per the culture results of patient body fluids or other signs of sepsis-like pneumonia, meningitis or obvious cellulitis etc, while presumed sepsis are all those cases with fever but no obvious focus of infection) were included in our study. Once the participants fulfilled the inclusion criteria, a detailed medical history was collected. Severe sepsis and septic shock were categorized as per the Surviving Sepsis Guidelines. Exclusion criteria included pregnancy, poly-trauma, the patient had major surgery in the past 30 days, the patient had prior do-not-resuscitate orders or had a known chronically deliberated disease like chronic kidney disease, a cerebrovascular accident, a seizure disorder, malignancy or the patient was categorized as P3 or P4 as per Emergency Triage Severity (ESI) acuity [16]. Data were collected on a predesigned datasheet after taking written informed consent. EWS consists of physiological parameters such as respiratory rate, temperature, pulse, oxygen saturation, blood pressure, and consciousness level; each of them is given a score for the assessment of seventy for the critical or non-critical patient. The score for each of the seven parameters is summed to calculate the EWS, which may range between zero and 15: the higher the score, the greater the deviation from normality (Table 1). No study-related therapeutic or diagnostic intervention was carried out. In addition, this study had gone through approval by the institutional ethical review with the 42201-EM-ERC-16 board.

  Early warning score point
  3 2 1 0 1 2 3
Respiratory rate <8 - 9-11 12-20 - 21-24 ≥25
Oxygen saturation ≤94 92-93 94-95 ≥96 - - -
Supplemental oxygen - Yes - No - - -
Pulse rate ≤40 - 41-50 51-90 91-110 111-130 ≥130
Systolic blood pressure ≤90 91-100 101-110 111-219 - - ≥220
Temperature ≤35° - 35.1-36° 36.1-38° 38.1-39° ≥39° -
Consciousness level* - - - A - - V, P, U

Data were analyzed on IBM SPSS Statistics for Windows, Version 21.0. (IBM Corp., Armonk, NY) and Prism GraphPad version 8.1.2 (GraphPad Software, San Diego, CA). Descriptive statistics were reported and included mean along with standard deviation for the age of the patient, the duration of concerns, and early warning score. Proportions and percentages for categorical variables were calculated for gender, sepsis, severe sepsis, and septic shock. The receiver operating characteristic (ROC) curve consists of the ratios obtained from the scores of each cut-off value (threshold), and the ratio that accurately predicts the actual default. True-positive rate and false-positive rate incorrectly predict actual normality as default is represented by graphs corresponding to Y-axis and X-axis coordinates, respectively.

Analysis of the ROC area under the curve (AUC) was calculated to see overall performances for sepsis, severe sepsis, and septic shock with EWS with 95% CI. Optimal cut-off values were chosen to maximize the sum of sensitivity (Se) and specificity (Sp). Positive predictive values, negative predictive values, positive likelihood ratios, and negative likelihood ratios were also assessed. All analyses were performed at 95% CI with a 5% level of significance.

Results

The mean and standard deviation of age 52.7 ± 15.3 (18 to 80 years), hospital length of stay (LOS) 2.2 ± 1.1 (one to six days), and EWS of 8.2 ± 2.6 (4 to 15), respectively. A higher mean significance value of age was observed in septic shock as compared to severe sepsis (53 ± 14 vs. 59 ± 14, P < .001). Patients who were in severe sepsis had a longer hospital stay as compared to septic shock (2.7 ± 0.8 vs. 2.4 ± 1.5, P < .001). In contrast, we also showed that the value of EWS increased in septic shock (8.8 ± 0.911 vs. 8 ± 1.3, P < .001)

We analyzed the demographic descriptions of the 240 patients enrolled, of whom 139 (57.9%) patients were men, and 101 (42.1%) were women. There were 143 patients in the elderly age group of > 50 years (59.6%). The least affected age group was aged 18 to 30 years, with 23 (9.6%) cases. There were 152 (63.3%) patients whose LOS was two days or fewer. One hundred twenty-seven (52.9%) patients were shifted to the critical care area (front) of ED. 67 (27.9%) were shifted to non-critical area (stepdown), and only 46 (19.2%) belonged to resuscitation, respectively. One hundred seventy-nine (74.6%) patients recovered and were discharged, but 47 patients (19.6%) died during the study period; only 14 (5.8%) of those patients had left against medical advice without justification. Categories of adult patients were stratified into three groups: 115 (47.9%) had sepsis, 68 (28.3%) had severe sepsis, and 57 (23.8%) had septic shock individually.

Associations with sepsis, severe sepsis, and septic shock are discussed in Table 2. A majority of our patients (n = 143; 59.6%) were older than 50 years. A majority of cases (n = 152; 63.3%) had hospital LOS ≤ 2 days. The ESI was also calibrated, and most patients (n = 154; 64.2%) were in category II. However, 90 patients (78.3%) had symptoms of sepsis (P < .0001). There was a mortality rate of 19.6% (n = 47). However, 30 of 47 (68%) mortality cases were of septic shock (P < .0001).

  Sepsis Severe Sepsis Septic Shock Total P-value
f (%) f (%) f (%) f (%)
Sex
Men 71 (61.7%) 39 (57.4%) 29 (50.9%) 139 (57.9%) .395
Women 44 (38.3%) 29 (42.6%) 28 (49.1%) 101 (42.1%)
Total 115 (100%) 68 (100%) 57 (100%) 240 (100%)
Age groups
≤ 50 Years 61 (53%) 23 (33.8%) 13 (22.8%) 97 (40.4%) <0.001
> 50 Years 54 (47%) 45 (66.2%) 44 (77.2%) 143 (59.6%)
Total 115 (100%) 68 (100%) 57 (100%) 240 (100%)
Length of hospital stay
≤ 2 days 88 (76.5%) 31 (45.6%) 33 (57.9%) 152 (63.3%) <0.001
> 2 days 27 (23.5%) 37 (54.4%) 24 (42.1%) 88 (36.7%)
Total 115 (100%) 68 (100%) 57 (100%) 240 (100%)
Disposition
Resuscitation 23 (20%) 12 (17.6%) 11 (19.3%) 46 (19.2%) <0.001
Front 59 (51.3%) 40 (58.8%) 28 (49.1%) 127 (52.9%)
Step down 33 (28.7%) 16 (23.5%) 18 (31.6%) 67 (27.9%)
Total 115 (100%) 68 (100%) 57 (100%) 240 (100%)
Fate
Discharged 108 (93.9%) 48 (70.6%) 23 (40.4%) 179 (74.6%) <0.001
Expired 0 (0%) 17 (25%) 30 (52.6%) 47 (19.6%)
Left against medical advice 7 (6.1%) 3 (4.4%) 4 (7%) 14 (5.8%)
Total 115 (100%) 68 (100%) 57 (100%) 240 (100%)  

The AUC for EWS to identify the patients with sepsis and severe sepsis at risk is 0.96 (95% CI: 0.933 to 0.989). An EWS >7 is best to detect the cases with sepsis and severe sepsis with a 98.5% Se (95% CI: 92.13 to 99.92) and 89.57% Sp (95% CI: 82.64 to 93.93), with a likelihood ratio of 9.44 (Table 3; Figure 1).

EWS cut-off ≥ Sensitivity % 95% CI Specificity % 95% CI Likelihood ratio
4 100 94.65% to 100.0% 5.217 2.413% to 10.92% 1.055
5 100 94.65% to 100.0% 26.96 19.69% to 35.71% 1.369
6 100 94.65% to 100.0% 70.43 61.54% to 78.01% 3.382
7 98.53 92.13% to 99.92% 89.57 82.64% to 93.93% 9.442
8 63.24 51.36% to 73.70% 97.39 92.61% to 99.29% 24.24
9 11.76 6.083% to 21.53% 98.26 93.88% to 99.69% 6.765
10 4.412 1.202% to 12.19% 99.13 95.24% to 99.96% 5.074
11 2.941 0.5226% to 10.10% 100 96.77% to 100.0%  

While elaborating for severe sepsis and septic shock on EWS, we found the AUC at 0.895 (95% CI: 0.836 to 0.953), and a score of >9 was best to detect cases with an 86.76% Se (95% CI: 76.72 to 92.88) and an 88.24% Sp (95% CI: 78.47 to 93.92), with a likelihood ratio of 7.375 (Table 4; Figure 2).

EWS cut-off ≥ Sensitivity % 95% CI Specificity % 95% CI Likelihood ratio
7 100 94.65% to 100.0% 1.471 0.07543% to 7.871% 1.015
8 92.65 83.91% to 96.82% 36.76 26.30% to 48.64% 1.465
9 86.76 76.72% to 92.88% 88.24 78.47% to 93.92% 7.375
10 70.59 58.89% to 80.08% 95.59 87.81% to 98.80% 16
11 52.94 41.24% to 64.33% 97.06 89.90% to 99.48% 18
12 26.47 17.45% to 38.01% 100 94.65% to 100.0% -
13 7.353 3.181% to 16.09% 100 94.65% to 100.0% -
14 1.471 0.07543% to 7.871% 100 94.65% to 100.0% -

Discussion

Sepsis is a common ED presentation and a leading cause of mortality among severely ill patients [17]. Early identification and initiation of adequate therapy are essential for surviving severe sepsis or septic shock. Therefore, EWS was used for the early diagnosis of sepsis in the emergency department. The objective of our study was to collect information regarding the utilization of EWS in timely identifying the sick patients at triage.

There are multiple scoring criteria for early and rapid identification of septic patients at triage such as sequential organ failure assessment and acute physiology and chronic health evaluation; however, other than physiological factors, most need laboratory parameters, which are almost impossible to obtain from sick patients at busy triage [18]. This score will not only help physicians in early detection and deterioration of septic patients but it will also guide our triage nurse to identify sepsis patient early and can start to initiate and follow their system algorithms that suggest appropriate interventions and management and prevent further deterioration to reduce mortality and LOS [19-21].

With this prospective study, we found that EWS is a sensitive tool in the early identification of sepsis, severe sepsis, and septic shock and may be used to detect a patient at risk. With scores of ≥ 7 with excellent Se of 98.5% and good Sp of 89.57%, these results are better than a similar study from Keep et al. [22]. Similarly, analyzing the same data, using EWS for severe sepsis and septic shock, we found promising results of ≥ 9 having a Se of 86.76% and an Sp of 88.24%. Hence, we may predict that patients with a high EWS are likely to be sicker at triage with more deranged physiological and clinical parameters; however, cut-off values of EWS for sepsis and septic shock are different.

Regarding the age and gender variables, we found similar patterns as Asghar et al. [23] and Morr et al. [24]. Elderly patients aged > 50 years were more prone to sepsis [25-28].

EWS can play a key role in the early diagnosis and management of sepsis because specific markers for sepsis are not accessible at triage, so a statistically valid, practical, and accurate scoring system could potentially save lives and improve outcomes, morbidity and mortality, for septic patients. Our mean average EWS was 8.2 ± 2.6 (range, 7 to 23), which helps identify all sorts of sepsis early [23,24,26-29].

Conclusions

An EWS score of >7 at ED presentation has high sensitivity and specificity for sepsis and severe sepsis. In contrast, an EWS >9 has high Se and Sp for severe sepsis and septic shock. Therefore, EWS could be a valuable tool for early identification and timely management of sepsis, severe sepsis, and septic shock.


References

  1. McGaughey J, Alderdice F, Fowler R, Kapila A, Mayhew A, Moutray M: Outreach and Early Warning Systems (EWS) for the prevention of intensive care admission and death of critically ill adult patients on general hospital wards. Cochrane Database Syst Rev. 2007, 18:005529. 10.1002/14651858.CD005529.pub2
  2. Russell JA, Walley KR, Singer J, et al.: Vasopressin versus norepinephrine infusion in patients with septic shock. N Engl J Med. 2008, 358:877-887. 10.1056/NEJMoa067373
  3. Sprung CL, Annane D, Keh D, et al.: Hydrocortisone therapy for patients with septic shock. N Engl J Med. 2008, 358:111-124. 10.1056/NEJMoa071366
  4. Khan NU, Razzak JA, Alam SM, Ahmad H: Emergency department deaths despite active management: experience from a tertiary care centre in a low-income country. Emerg Med Australas. 2007, 19:213-217. 10.1111/j.1742-6723.2007.00920.x
  5. Vincent J-L, Abraham E, Annane D, Bernard G, Rivers E, Van den Berghe G: Reducing mortality in sepsis: new directions. Crit Care. 2002, 6:1-18. 10.1186/cc1860
  6. Rivers EP, Coba V, Whitmill M: Early goal-directed therapy in severe sepsis and septic shock: a contemporary review of the literature. Curr Opin Anaesthesiol. 2008, 21:128-140. 10.1097/ACO.0b013e3282f4db7a
  7. Knaus WA, Draper EA, Wagner DP, Zimmerman JE: APACHE II: a severity of disease classification system. Crit Care Med. 1985, 13:818-829.
  8. Knaus WA, Zimmerman JE, Wagner DP, Draper EA, Lawrence DE: APACHE—acute physiology and chronic health evaluation: a physiologically based classification system. Crit Care Med. 1981, 9:591-597. 10.1097/00003246-198108000-00008
  9. Gall J-R Le, Loirat P, Alperovitch A, et al.: A simplified acute physiology score for ICU patients. Crit Care Med. 1984, 12:975-977. 10.1097/00003246-198411000-00012
  10. Lemeshow S, Teres D, Klar J, Avrunin JS, Gehlbach SH, Rapoport J: Mortality Probability Models (MPM II) based on an international cohort of intensive care unit patients. JAMA. 1993, 270:2478-2486. 10.1001/jama.1993.03510200084037
  11. Vincent J-L, Moreno R, Takala J, et al.: The SOFA (Sepsis-related Organ Failure Assessment) score to describe organ dysfunction/failure. Intensive Care Med. 1996, 22:707-710. 10.1007/BF01709751
  12. Higgins TL, Teres D, Copes WS, Nathanson BH, Stark M, Kramer AA: Assessing contemporary intensive care unit outcome: an updated Mortality Probability Admission Model (MPM0-III). Crit Care Med. 2007, 35:827-835. 10.1097/01.CCM.0000257337.63529.9F
  13. Moreno RP, Metnitz PGH, Almeida E, et al.: SAPS 3—From evaluation of the patient to evaluation of the intensive care unit. Part 2: Development of a prognostic model for hospital mortality at ICU admission. Intensive Care Med. 2005, 31:1345-1355. 10.1007/s00134-005-2763-5
  14. Zimmerman JE, Kramer AA, McNair DS, Malila FM: Acute Physiology and Chronic Health Evaluation (APACHE) IV: hospital mortality assessment for today’s critically ill patients. Crit Care Med. 2006, 34:1297-1310. 10.1097/01.CCM.0000215112.84523.F0
  15. Morgan RJ, Williams F, Wright MM: An early warning scoring system for detecting developing critical illness. Clin Intensive Care . 1997, 8:100.
  16. Grossmann FF, Nickel CH, Christ M, Schneider K, Spirig R, Bingisser R: Transporting clinical tools to new settings: cultural adaptation and validation of the Emergency Severity Index in German. Ann Emerg Med. 2011, 57:257-264. 10.1016/j.annemergmed.2010.07.021
  17. Balk RA: Severe sepsis and septic shock. Crit Care Clin. 2000, 16:179-192. 10.1016/S0749-0704(05)70106-8
  18. Ho KM: Combining sequential organ failure assessment (SOFA) score with acute physiology and chronic health evaluation (APACHE) II score to predict hospital mortality of critically ill patients. Anaesth Intensive Care. 2007, 35:515-521. 10.1177/0310057X0703500409
  19. Salvo I, de Cian W, Musicco M, et al.: The Italian SEPSIS study: preliminary results on the incidence and evolution of SIRS, sepsis, severe sepsis and septic shock. Intensive Care Med. 1995, 21:244-249. 10.1007/BF01740762
  20. Pittet D, Thiévent B, Wenzel RP, Li N, Auckenthaler R, Suter PM: Bedside prediction of mortality from bacteremic sepsis. A dynamic analysis of ICU patients. Am J Respir Crit Care Med. 1996, 153:684-693. 10.1164/ajrccm.153.2.8564118
  21. McGaughey J, O’Halloran P, Porter S, Blackwood B: Early warning systems and rapid response to the deteriorating patient in hospital: a systematic realist review. J Adv Nurs. 2017, 73:2877-2891. 10.1111/jan.13398
  22. Keep J, Messmer A, Sladden R, Burrell N, Pinate R, Tunnicliff M, Glucksman E: National early warning score at Emergency Department triage may allow earlier identification of patients with severe sepsis and septic shock: a retrospective observational study. Emerg Med J. 2016, 33:37-41. 10.1136/emermed-2014-204465
  23. Asghar A, Hashmi M, Rashid S, Khan FH: Incidence, outcome and risk factors for sepsis-a two year retrospective study at surgical intensive care unit of a teaching hospital in Pakistan. J Ayub Med Coll. 2016, 28:79-83.
  24. Morr M, Lukasz A, Rübig E, Pavenstädt H, Kümpers P: Sepsis recognition in the emergency department - impact on quality of care and outcome?. BMC Emerg Med. 2016, 17:11. 10.1186/s12873-017-0122-9
  25. Angus DC, Linde-Zwirble WT, Lidicker J, Clermont G, Carcillo J, Pinsky MR: Epidemiology of severe sepsis in the United States: analysis of incidence, outcome, and associated costs of care. Crit Care Med. 2001, 29:1303-1310.
  26. McNevin C, McDowell R, Fitzpatrick F, O’Sullivan R, Wakai A: The prevalence of severe sepsis or septic shock in an Irish emergency department. Ir Med J. 2018, 111:692.
  27. Wang HE, Shapiro NI, Angus DC, Yealy DM: National estimates of severe sepsis in United States emergency departments. Crit Care Med. 2007, 35:1928-1936. 10.1097/01.CCM.0000277043.85378.C1
  28. Majuran M, Clancy M: Determination of the size of the different sepsis categories presenting to a UK teaching hospital emergency department. Emerg Med J. 2008, 25:11-14. 10.1136/emj.2006.042358
  29. Bayer O, Schwarzkopf D, Stumme C, et al.: An early warning scoring system to identify septic patients in the prehospital setting: the PRESEP score. Acad Emerg Med. 2015, 22:868-871. 10.1111/acem.12707
Original article
peer-reviewed

The Utility of Early Warning Score in Adults Presenting With Sepsis in the Emergency Department of a Low Resource Setting


Author Information

Emaduddin Siddiqui Corresponding Author

Emergency Medicine, Aga Khan University Hospital, Karachi, PAK

Abdul A. Jokhio

Emergency Medicine, Dow University of Health Sciences, Karachi, PAK

Ahmed Raheem

Pathology and Laboratory Medicine, Aga Khan University Hospital, Karachi, PAK

Shahan Waheed

Emergency Department, Aga Khan University Hospital, Karachi, PAK

Syed Hashmatullah

Psychiatrist Adult & Addiction Services, Grey Bruce Health Services, Ontario, CAN


Ethics Statement and Conflict of Interest Disclosures

Human subjects: Consent was obtained by all participants in this study. Aga Khan University & Hospital issued approval 4220-EM-ERC-16. Thank you for your response to ERC recommendation received on May 11,2016 regarding the above mentioned study.
Your response adequate answered the recommendations made by the committee. The study was given approval for a period of one year.
All informed consent should be retained for future references. A progress report should be submitted to ERC office after six months.
Thank you
your sincerely
Dr. Shaista Khan , FRCS (Edin)
Chariperson
Ethical Review Committee. Animal subjects: All authors have confirmed that this study did not involve animal subjects or tissue. Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following: Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work. Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work. Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work.


Original article
peer-reviewed

The Utility of Early Warning Score in Adults Presenting With Sepsis in the Emergency Department of a Low Resource Setting