Comparison of 11C-choline Positron Emission Tomography/Computed Tomography (PET/CT) and Conventional Imaging for Detection of Recurrent Prostate Cancer



Abstract

We aimed to compare 11C-choline positron emission tomography/computed tomography (PET/CT) with conventional imaging, including pelvic magnetic resonance imaging (MRI), contrast-enhanced chest, abdomen, and pelvic computed tomography (CT), and bone scintigraphy, for prostate cancer restaging. Thirty patients (median prostate-specific antigen [PSA: 11.8 ng/mL]) with suspected recurrent prostate cancer following definitive treatment underwent 11C-choline PET/CT and conventional imaging, including pelvic MRI, contrast-enhanced chest, abdomen, and pelvic CT, and bone scintigraphy. The results were compared with regard to patient- and lesion-based diagnostic performance for local recurrence, and for lymph node and bony metastases using receiver operating characteristic (ROC) analysis and McNemar’s test. Documented local recurrence and node and bony metastases were present in 11 (36.7%), 10 (33.3%), and 17 (56.7%) cases, respectively, of the enrolled patients. Patient-based sensitivity / specificity / accuracy / area under the ROC curve for 11C-choline-PET/CT for diagnosing local recurrence were 90.9% / 94.7% / 93.3% / 0.975 and for conventional imaging were 90.9% / 100% / 96.7% / 1.0. Those who underwent 11C-choline-PET/CT for node metastasis were 90.0% / 95.0% / 93.3% / 0.925 and for conventional imaging were 70.0% / 95.0% / 86.7% / 0.905. Those who underwent 11C-choline-PET/CT for bone metastasis were 94.1% / 92.3% / 93.3% / 0.991 and who underwent conventional imaging were 94.1% / 84.6% / 90.0% / 0.982. No significant differences were observed among them. The lesion-based detection rate of 11C-choline PET/CT for local recurrences and node and bone metastases as compared to conventional imaging was 92.9% (13/14) vs. 92.9% (13/14); 87.1% (27/31) vs. 54.8% (17/31); and 96.9% (219/226) vs. 90.3% (204/226) respectively, with significant differences noted for detection of node and bone lesions (p=0.0044 and p=0.00030, respectively). 11C-choline-PET/CT is more accurate in the detection of recurrent prostate cancer nodes and bony metastatic lesions compared to conventional imaging and has the advantage of restaging the disease in a single step.

Introduction

In Western Europe and North America, prostate cancer is the most common tumor type in men and the second-most frequent cause of all deaths from cancer [1]. Although prostate cancer often develops slowly, it can later show an aggressive pattern and sometimes recurrence. For patients with recurrent prostate cancer, it is important to determine whether there is localized recurrent disease, metastasis to lymph nodes or bone, or a combination of localized recurrent and metastatic disease. This affects the subsequent management, such as consideration of salvage therapy for localized recurrence, systemic treatment for metastatic disease, or a combination of these. Computed tomography (CT), bone scintigraphy, pelvic magnetic resonance imaging (MRI), and trans-rectal ultrasound examinations have been traditionally used to determine the localization of recurrent or metastatic disease, though they lack the adequate sensitivity and accuracy. In recent years, positron emission tomography/computed tomography (PET/CT) using 11C- or 18F-choline has emerged as a promising molecular imaging tool and can provide full-body examination results in a single step [2-4].

No known study has been presented so far that directly compares the diagnostic capability of 11C-choline PET/CT with that of conventional imaging, including pelvic MRI, contrast-enhanced chest, abdomen, and pelvic CT, and bone scintigraphy, for restaging prostate cancer that has recurred following definitive treatment. Picchio et al. [5] compared 11C-choline PET with conventional imaging, including pelvic MRI, CT, bone scintigraphy, and trans-rectal ultrasound, for restaging of prostate cancer, but not PET/CT, though PET using 11C-choline was done while other modalities (pelvic MRI, CT, bone scintigraphy, trans-rectal ultrasound) were not performed in all of the enrolled patients. In addition, Beauregard et al. [6] compared 11C-choline PET/CT with conventional imaging, including pelvic CT and bone scintigraphy, for staging and restaging of prostate cancer, though pelvic MRI was not performed. Thus, the superiority of 11C-choline PET/CT over conventional imaging modalities, including pelvic MRI, contrast-enhanced chest, abdomen, and pelvic CT, and bone scintigraphy, for restaging of prostate cancer in patients who have undergone definitive treatment, has yet to be confirmed. The purpose of the present study was to clarify which method is preferable for the detection of local recurrence, as well as lymph node and bone metastasis in patients suspected to have recurrent prostate cancer.

Materials & Methods

This retrospective study was performed in accordance with the principles of the declaration of Helsinki. The institutional review board (Hyogo University Hospital, Japan) approved this retrospective study (No 2019). Informed consent was obtained from each patient after the procedure details were fully explained.

Patients

A total of 30 males (mean age 71.3 years, range 47-90 years) with suspected recurrent prostate cancer after receiving definitive treatment were included in this study and underwent 11C-choline PET/CT as well as conventional imaging, including pelvic MRI, contrast-enhanced chest, abdomen, and pelvic CT, and bone scintigraphy, at our institution between October 2015 and July 2017, with a maximum interval of two weeks between examinations. The median serum prostate-specific antigen (PSA) level in our cohort was 11.8 ng/mL (range 0.23-946 ng/mL). At the time of the examination, 26 (86.7%) of the 30 patients had received androgen-deprivation therapy. Additional patient details are shown in Table 1.

Characteristics Value
Age (years)  
 Mean 71.3±9.0
 Range 4790
PSA (ng/mL)  
 Mean 65.2±177.4
 Range 0.23946
 Median 11.8
Previous treatment  
 Radiotherapy 2
 Surgery 1
 Hormonal therapy 16
 Radiotherapy+hormonal therapy 10
 Hormonal therapy+chemotherapy 1

11C-choline PET/CT

11C-choline was synthesized using a commercial module, as described by Hara [7], and a CYPRIS-325R cyclotron (SHI, Tokyo, Japan). Acquisition of emission scan images from the mid-thigh to the head was started six minutes after intravenous injection of 3.0 MBq/kg body weight of 11C-choline. All PET/CT examinations were performed using a PET/CT scanner equipped with a 64-multidetector computed tomography device (Gemini TF64; Philips Medical Systems, Eindhoven, The Netherlands). The whole-body PET image acquisition in 3D mode was performed from the mid-thigh to the top of the head (1.5 minutes per bed position; 6-8 bed positions) and the obtained images were reconstructed using the ordered subsets expectation maximization reconstruction algorithm (33 subsets, three iterations, 4 mm per slice), with attenuation correction based on low-dose CT (120 kVp, 100 mA, slice thickness 2 mm, transverse field of view 600 mm), which was also used for anatomical correlations.

Conventional imaging

Pelvic MRI

The MRIs were performed using a Magnetom Avanto 1.5-T (Siemens Medical Solutions, Erlangen, Germany) or an Intera 1.5T (Philips Healthcare, Amsterdam, The Netherlands) system, equipped with a body coil for excitation and pelvic phased array coil for signal reception. Axial, coronal, and sagittal fast-spin-echo T2-weighted imaging (T2WI) were performed with a repetition time (TR)/echo time (TE) of 4000-4750 ms/110-120 ms, 3 mm slice thickness/0.3 mm gap, 28×22 cm field of view (FOV), and 228×256-256×320 matrix. T1-weighted imaging (T1WI) was performed in the axial plane with a spin-echo TR/TE of 500-550/9-10 ms, 3 mm slice thickness/0.3 mm gap, 28×22 cm FOV, and 228×256-256×320 matrix. Axial diffusion-weighted imaging (DWI) was performed along three orthogonal directions using spin-echo-type single-shot echo planar imaging with the following parameters: b value=0 and 1000 ms/mm2, TR/TE=3500-4500/70-75 ms, 3 mm slice thickness/0.3 mm gap, 42×32 cm FOV, and 128×108 matrix. In addition, coronal T1WI and T2WI were performed with a 3 mm slice thickness/0.3 mm gap, 59×30 cm FOV, and 228×256-256×320 matrix.

Contrast-enhanced CT

Pre-contrast and contrast-enhanced multi-detector CT (MDCT) images of the chest, abdomen, and pelvis were obtained using a 128-detector row CT device (SOMATOM Definition AS+, Siemens Medical Solutions, Erlangen, Germany) at 120 kV and effective mAs of 220 (CARE Dose4D), beam pitch of 0.6, collimation of 1.2 mm×32, and B31 + medium smooth + image reconstruction. Blood creatinine and the estimated glomerular filtration rate (eGFR) level were checked in all the patients before the examination. Iodinated contrast material (IopamironInj, Bayer Schering Pharma, Berlin, Germany) containing 300 mg of iodine per ml at a dose of 600 mg iodine per kilogram of body weight was intravenously administered using a power injector. The scan was started at 120 seconds after the injection to obtain venous phase images.

Bone scintigraphy

Whole-body bone scintigraphy was performed using a dual-head gamma camera (Forte, Hitachi, Tokyo, Japan) after intravenous administration of approximately 555 MBq of 99mTc-methylene diphosphonate (99mMDP) (FujiFilm RI Pharma, Tokyo, Japan). Following the injection, the patient was orally hydrated and asked to void their bladder frequently as well as immediately prior to the scan. Total body images were obtained approximately three hours after administration of 99mMDP, with simultaneous anterior and posterior whole-body acquisition. Static additional acquisitions were acquired when needed. Single-photon emission computed tomography (SPECT) images were not acquired.

Imaging analysis

Two board-certified nuclear medicine physicians with no knowledge of the other imaging results or the final diagnosis interpreted the 11C-choline PET/CT findings, then used a five-point scale (1: definitely absent, 2: probably absent, 3: indeterminate, 4: probably present, 5: definitely present) to grade lesions in each patient based on consensus. Discordant readings by the two observers were resolved by a subsequent consensus review.

Focal 11C-choline activity in the prostate or a seminal vesicle greater than that in the adjacent background and not due to excreted radiotracer in urine was graded as 4 or 5 regardless of a corresponding structural abnormality. Lymph nodes were graded as 4 or 5 if distinct focal activity on the PET images was co-registered to a visible lymph node in CT images regardless of size. Focal skeletal sites of uptake above background marrow activity were graded as 4 or 5 unless inflammatory change, degenerative change, or fracture was evident. Semiquantitative analysis of abnormal radiotracer uptake for each lesion was also retrospectively performed using a maximum standardized uptake value (SUVmax), calculated as follows: SUV = volume of interest (VOI) radioactivity concentration (Bq/mL)/[injected dose (Bq)/patient weight (g)]. SUVmax, defined as the highest SUV value for pixels with the highest count within the VOI, was determined and recorded for the focal areas of uptake.

Two board-certified observers, a double board-certified nuclear medicine physician and radiologist, and a board-certified radiologist, with no knowledge of the other imaging results, or the final results, interpreted the conventional imaging findings and then used the same five-point scale to grade the lesions in each patient based on consensus. Discordant readings by the two observers for each modality were resolved by a subsequent consensus review.

The status of local recurrence was evaluated by pelvic MRI results. When T2WI findings were reviewed, a mass or soft-tissue area showing abnormal signal intensity was considered a positive finding (confidence score 4 or 5). In a review of DWI findings and apparent diffusion coefficient (ADC) maps, the presence of a lesion with high focal signal intensity on a DW image and low signal intensity on the ADC map relative to the background was considered to be a positive finding (score 4 or 5). Two positive interpretations of images in two sequences were given a confidence score of 5, while one positive interpretation in two sequences was given a score of 3 or 4. The number, location, and long-axis dimension of the suspected locally recurrent lesions were recorded.

The status of lymph node metastasis was evaluated by pelvic MRI as well as contrast-enhanced chest, abdomen, and pelvic CT findings. For scoring nodal status based on CT and MRI results, the following diagnostic criteria were used: short-axis diameter of node ≥10 mm, score 5; 8-9.9 mm, score 4; 5-7.9 mm, score 3; 1-4.9 mm, score 2; not seen, score 1. The number, location, and short-axis dimension of the suspected nodal metastatic lesions were recorded.

Bone metastasis status was also evaluated based on the combination of bone scintigraphy, contrast-enhanced chest, abdomen, and pelvic CT, and pelvic MRI findings. In bone scintigraphy images, a lesion was defined as malignant according to standard pathological criteria of intensity, localization, and the extension of 99mMDP uptake, with physiological uptake due to inflammatory change, degenerative change, or fracture excluded (score 4 or 5). In CT images, a lesion with osteoblastic or osteolytic change was graded as 4 or 5, unless inflammatory change, degenerative change, or fracture was evident. A lesion showing low signal intensity on T1WI and abnormal signal intensity on a DWI/ADC map is considered to be a positive finding (score 4 or 5). Inside the pelvis, three positive interpretations in three modalities were given a confidence score of five; two positive interpretations in three modalities a score of 4 or 5, and one positive interpretation a score of 3 or 4. Outside the pelvis, two positive interpretations of images in two sequences were given a confidence score of 5 and one positive interpretation in two sequences received a score of 3 or 4.

Gold standard

The final diagnosis was obtained based on histological confirmation, radiological imaging findings, or clinical follow-up results at least six months, including PSA level, MRI, CT, bone scintigraphy, and 11C-choline PET/CT findings.

Statistical analysis

To determine the utility of each imaging modality, receiver-operating-characteristic (ROC) analysis was employed. A ROC contrast estimation was utilized to compare the diagnostic capability of the two types of modalities on a per-patient basis. To test whether the area under the ROC curve (AUC) values were different, correlations of the testing methods were accounted for in the analysis. Tests for differences in sensitivity, specificity, and accuracy between the types of modalities were conducted using McNemar’s test. To calculate the sensitivity and specificity of each modality, scores of 4 and 5 were considered positive. A p-value of less than 0.05 was considered to indicate a statistically significant difference. All statistical analyses were performed using SAS software, version 9.3 (SAS Institute).

Results

Local recurrence

Eleven (36.7%) of the 30 patients were found to have a total of 14 local recurrent lesions (12 in the prostate gland, two in the seminal vesicles). The SUVmax values and long-axis diameters for these locally recurrent lesions as shown by 11C-choline PET/CT and conventional imaging were 6.74±2.92 (1.65-12.91) and 19.9±8.6 mm (9-35 mm), respectively. The patient- and lesion-based sensitivities of 11C-choline PET/CT as compared to conventional imaging were 90.9% (10/11) vs. 90.9% (10/11), and 92.9% (13/14) vs. 92.9% (13/14), respectively (Table 2-3). Case 1 shows that local recurrence in the prostate gland could be diagnosed by both  11C-choline PET/CT (Figures 1-2) and pelvic MRI (Figure 2).

  Sensitivity Specificity Accuracy AUC
  95%CI 95%CI 95%CI 95%CI
Local recurrence        
11C-choline PET/CT 90.9% 94.7% 93.3% 0.975
  73.1100% 84.4100% 84.4100% 0.85-0.996
Conventional imaging 90.9% 100% 96.7% 1.0
  73.1100% 100% 90.2100% 1.0
p value 1.0 1.0 1.0 0.30
Lymph node metastasis        
11C-Choline PET/CT 90.0% 95.0% 93.3% 0.925
  41.698.4 % 85.4100% 84.4100% 0.596-0.990
Conventional imaging 70.0% 95.0% 86.7% 0.905
  53.686.4% 85.4100% 73.898.8% 0.615-0.983
p-value 0.48 1.0 0.48 0.28
Bone metastasis        
11C-Choline PET/CT 94.1% 92.3% 93.3% 0.991
  82.9100% 77.8100% 84.4100% 0.918-0.999
Conventional imaging 94.1% 84.6% 90.0% 0.982
  82.9100% 65.0100% 79.3100% 0.902-0.997
p-value 1.0 1.0 1.0 0.39
All lesions        
11C-Choline PET/CT 92.0% 100% 93.3% 0.964
  81.4100% 100% 84.4100% 0.828-0.993
Conventional imaging 92.0% 80.0% 90.0% 0.976
  81.4100% 44.9100% 79.3100% 0.812-0.997
p value 1.0 1.0 1.0 0.71

One false-negative case in the 11C-choline PET/CT findings was a tiny (9 mm) local recurrent lesion in the prostate gland that showed faint 11C-choline uptake (SUVmax 1.65). Another false-negative case which was determined by conventional imaging was a local recurrence in the seminal vesicles measuring 14 mm, which showed moderate 11C-choline uptake (SUVmax 4.53). One false-positive case was choline nonspecific uptake (SUVmax 4.84) in the prostate gland shown by 11C-choline PET/CT (Figures 1-2).

 

Lymph node metastasis

Ten (33.3%) of the 30 patients had a total of 31 metastatic lymph nodes (six external iliac, five internal iliac, two obturator, four common iliac, eight abdominal para-aortic, three mediastinal, and three supraclavicular). The SUVmax values and short-axis diameters of those metastatic nodes as shown by 11C-choline PET/CT and conventional imaging were 5.48±3.21 (0.89-13.9) and 10.1±5.8 mm (4-25 mm), respectively. The patient- and lesion-based sensitivity of 11C-choline PET/CT as compared to conventional imaging was 90.0% (9/10) vs. 70.0% (7/10), and 87.1% (27/31) vs. 54.8% (17/31), respectively (p=0.48 and p=0.0044, respectively) (Tables 2-3). Case 1 shows that a tiny pelvic lymph node metastasis could be diagnosed by 11C-choline PET/CT, but not contrast-enhanced CT (Figure 3).

 

Four false-negative cases were determined by 11C-choline PET/CT and consisted of two tiny para-aortic metastatic nodes measuring 4 and 5 mm, respectively (one tiny internal iliac node measuring 6 mm and one tiny external iliac node measuring 6 mm). Those four nodal lesions showed no or faint 11C-choline uptake (SUVmax: 0.89, 1.21, 1.49, and 1.77). Fourteen false-negative cases were determined by conventional imaging and were all tiny lesions whose short-axis diameter measured less than 8 mm. One false-positive case determined by 11C-choline PET/CT showed 11C-choline nonspecific uptake (SUV max: 3.61) in the inguinal node. One false-positive case was also determined by conventional imaging and had non-specific enlarged hilar and mediastinal nodes measuring larger than 10 mm.

  11C-choline PET/CT Conventional imaging p value
Local Recurrence      
  Sensitivity 92.9% 92.9% 1
    95% CI 79.4100% 79.4100%  
  SUVmax of all 14 lesions 6.74±2.92    
  Lesion long diameter of all 14 lesions   19.9±8.6 mm  
Lymph node metastasis      
  Sensitivity 87.1% 54.8% 0.0044
     95% CI 75.398.9% 37.372.4%  
  SUVmax of all 31 lesions 5.48±3.21    
  Lesion short diameter of all 31 lesions   10.1±5.8 mm  
Bone metastasis      
  Sensitivity 96.9% 90.3% 0.00030
     95% CI 94.699.2% 86.494.1%  
  SUVmax of all 226 lesions 5.23±2.59    
All lesions      
  Sensitivity 95.6% 86.3% <0.0001
  95% CI 93.198.0% 82.390.4%  
 

Bone metastasis

Seventeen (56.7%) of the 30 patients had a total of 226 metastatic bone lesions (16 cervical spine, 36 thoracic spine, 21 lumbar spine, 17 sacrum, 22 iliac bone, 16 pubic, 16 ischium, 15 acetabulum, six sternum, four clavicle, 22 ribs, 13 scapula, eight upper extremities, 11 lower extremities, and three skull). The mean SUVmax value of the 226 bone metastases shown by 11C-choline PET/CT was 5.23±2.59 (range 1.77-14.62). The patient- and lesion-based sensitivity of 11C-choline PET/CT as compared to conventional imaging was 94.1% (16/17) vs. 94.1% (16/17), and 96.9% (219/226) vs. 90.3% (204/226), respectively (p=1.0 and p=0.00030, respectively) (Table 2-3). Inside the pelvis, the lesion-based sensitivity of 11C-choline PET/CT and conventional imaging for the sacrum, iliac bone, pubic, ischium, and acetabulum was the same (84/86, 97.7%). On the other hand, outside the pelvis, lesion-based sensitivity of 11C-choline PET/CT was 96.4% (135/140) as compared to 85.7% (120/140) for conventional imaging (p=0.00030) of the cervical spine, thoracic spine, lumbar spine, sternum, clavicle, ribs, scapula, upper extremities, lower extremities, and skull. Case 2 shows that multiple bone metastases could be detected by 11C-choline PET/CT (Figures 4-5), pelvic MRI (Figure 5), and bone scintigraphy (Figure 6). Table 4 presents the distribution and visualization rates of bone metastases shown by 11C-choline PET/CT and conventional imaging.

 
 
 
Location Lesion no. Sensitivity of 11C-choline PET/CT Sensitivity of Conventional imaging p value
Cervical spine 16 93.8%  93.8% 1
Thoracic spine 36 94.4%  94.4% 1
Lumbar spine 21 90.5%  90.5% 1
Sacrum 17 94.1%  94.1% 1
Iliac bone 22 100%  95.5% 1
Pubic 16 100%  100% 1
Ischium 16 93.8%  93.8% 1
Acetabulum 15 100%  100% 1
Sternum 6 100%  83.3% 1
Clavicle 4 100% 75.0% 1
Ribs 22 100% 77.3% 0.074
Scapula 13 100% 76.9%  0.25
Upper extremities 8 100%
100%  
0.48
Lower extremities 11 100% 81.8% 0.48
Skull 3 100% 66.7% 1
Total 226 96.9% 90.3% 0.00030
 
Location Lesion no. Sensitivity of 11C-choline PET/CT Sensitivity of Conventional imaging p value
Cervical spine 16 93.8%  93.8% 1
Thoracic spine 36 94.4%  94.4% 1
Lumbar spine 21 90.5%  90.5% 1
Sacrum 17 94.1%  94.1% 1
Iliac bone 22 100%  95.5% 1
Pubic 16 100%  100% 1
Ischium 16 93.8%  93.8% 1
Acetabulum 15 100%  100% 1
Sternum 6 100%  83.3% 1
Clavicle 4 100% 75.0% 1
Ribs 22 100% 77.3% 0.074
Scapula 13 100% 76.9%  0.25
Upper extremities 8 100%
100%  
0.48
Lower extremities 11 100% 81.8% 0.48
Skull 3 100% 66.7% 1
Total 226 96.9% 90.3% 0.00030
 

Eight false-negative cases shown by 11C-choline PET/CT were composed of one cervical spine, two thoracic spine, two lumbar spine, one sacrum, and one ischium case, while 22 false-negative cases shown by conventional imaging were composed of one cervical spine, two thoracic spine, one lumbar spine, one sacrum, one iliac bone, one ischium, one sternum, one clavicle, five ribs, three scapula, two upper extremities, two lower extremities, and one skull case. One false-positive case shown by 11C-choline PET/CT had moderate 11C-choline uptake (SUVmax: 4.13) observed in a normal thoracic vertebra, and false-positive cases shown by conventional imaging were degenerative changes in the cervical and lumbar vertebra, which showed strong 99mMDP uptake and osteoblastic changes in CT images.

All lesions

There was a total of 271 recurrent or metastatic lesions in 25 (83.3%) of the 30 patients. Patient-based analysis showed that the sensitivity, specificity, accuracy, and AUC of 11C-choline PET/CT were 92.0% (23/25), 100% (5/5), 93.3% (28/30), and 0.964, respectively, whereas those of conventional imaging were 92.0% (23/25), 80.0% (4/5), 90.0% (27/30), and 0.976, respectively (Table 2). No significant differences were observed among those four parameters. The lesion-based sensitivity of 11C-choline PET/CT as compared to conventional imaging was 95.6% (259/271) vs. 86.3% (234/271) (p<0.0001) (Table 3).

Discussion

The present is the first study to directly compare the diagnostic capability of 11C-choline PET/CT with that of conventional imaging, including pelvic MRI, contrast-enhanced chest, abdomen, and pelvic CT, and bone scintigraphy, for restaging prostate cancer in patients who have undergone definitive treatment. We found that the lesion-based sensitivity of 11C-choline PET/CT for detection of node and bone metastases in patients with recurrent prostate cancer was significantly higher as compared to conventional imaging modalities, with 11C-choline PET/CT and conventional imaging exhibiting equal sensitivity for the diagnosis of local recurrent disease. Although patient-based analysis did not reveal a significant difference between the two types of imaging, our results confirm those of a previous study, in which Picchio et al. [5] demonstrated that the patient-based sensitivity of 11C-choline PET and conventional imaging for restaging prostate cancer was 47% and 49%, respectively.

In Western countries, 11C- and 18F-choline PET/CT have been successfully used for restaging prostate cancer in patients with biochemical disease recurrence after undergoing definitive therapy, especially in those with a PSA level >1.0 ng/mL [2, 4, 8]. Another systematic review and meta-analysis of 19 selected studies with a total of 1,555 patients reported a pooled sensitivity of 85.6% and a pooled specificity of 92.6% [9]. Picchio et al. concluded that the routine use of 11C-choline PET/CT for restaging prostate cancer after a radical prostatectomy cannot be recommended for patients with a PSA value <1 ng/mL [8]. Furthermore, they noted that in addition to the PSA value, PSA doubling time and other clinical and pathological features, such as a locally advanced tumor (pT3a-T4) or nodal involvement at the initial staging, should be considered when considering patients for 11C-choline PET/CT.

The current gold standard for the diagnosis of a locally recurrent prostate cancer in patients who have undergone a radical prostatectomy procedure and radiation therapy is a dynamic gadolinium contrast-enhanced MRI [10-11]. Dynamic contrast-enhanced MRI was not performed in the present cases, thus the sensitivity of conventional imaging for local recurrence may have been underestimated. Kitajima et al. [3] compared multi-parametric MRI modalities, including T2WI, DWI, and dynamic contrast-enhanced imaging, with 11C-choline PET/CT for detection of local recurrence after a radical prostatectomy in 87 patients and reported that patient-based sensitivity, specificity, and accuracy of multi-parametric MRI were 88.5%, 84.6%, and 87.4%, respectively, whereas they were 54.1%, 92.3%, and 65.5%, respectively, for 11C-choline PET/CT.

Evaluation of lymph node metastasis is crucial for restaging patients with PSA failure after treatment. In a study of 25 prostatectomy patients with PSA failure using pelvic and retroperitoneal lymphadenectomy histopathology results as a reference [12], the values for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 11C-choline PET/CT for depicting nodal metastasis were 100%, 66%, 90%, 100%, and 92% respectively, in patient-based analysis and 64%, 90%, 86%, 72%, and 77% respectively, in lesion-based analysis. The low negative predictive value for lesion-based analysis in that the study indicated the limited performance of 11C-choline PET/CT in detecting microscopic nodal metastasis, whereas the high positive predictive value is an important result for facilitation of appropriate treatment. Kitajima et al. [3] also compared pelvic MRI and 11C-choline PET/CT results for detecting pelvic nodal metastasis following a radical prostatectomy in 70 patients, and they reported that the patient-based sensitivity, specificity, and accuracy values for pelvic MRI were 64.0%, 85.0%, and 70.0%, respectively, whereas those of 11C-choline PET/CT were 90.0%, 100%, and 92.9%, respectively. In the present study, we also noted the superiority of 11C-choline PET/CT as compared to MRI results.

In the present patient series, the ability to diagnose metastasis to the bone outside of the pelvis was significantly different between 11C-choline PET/CT and conventional imaging (bone scintigraphy and CT), whereas with regard to metastasis to bone inside the pelvis, it was the same between the imaging types because of the features of MRI. Bone scintigraphy is a low-cost whole-body clinical examination method commonly used to detect skeletal involvement in patients with prostate cancer, though it is known to be inferior to 11C-choline PET/CT for the detection of bone metastases. A previous meta-analysis demonstrated that the pooled sensitivity and specificity of 11C-choline PET/CT were 0.91 (95% confidence interval (CI): 0.83–0.96) and 0.99 (95% CI: 0.93–1.00), respectively, while those values for bone scintigraphy were 0.79 (95% CI: 0.73–0.83) and 0.82 (95% CI: 0.78–0.85), respectively [13]. Similar to the findings of the present cohort, Kitajima et al. [3] reported equally excellent accuracy for the diagnosis of pelvic bone metastases after undergoing a radical prostatectomy in 95 patients, with values for patient-based sensitivity, specificity, and accuracy for pelvic MRI found to be 87.5%, 96.2%, and 94.7%, respectively, whereas those for 11C-choline PET/CT were 81.3%, 98.7%, and 95.8%, respectively. Although the superiority of 11C-choline PET/CT as compared to the whole-body MRI is controversial [13-14] and further analysis is needed, we consider that it is necessary to use 11C-choline PET/CT or a whole-body MRI for a careful examination to check for whole-body bone metastasis. In contrasting reports, a group reported the superiority of the whole-body MRI [13], while another found that 11C-choline PET/CT was superior [14].

Our study has some limitations, including the small number of patients enrolled from a single institution. A prospective multicenter trial with a larger cohort would help to clarify the exact role of 11C-choline PET/CT in clinical decision-making and long-term outcomes in clinical settings. Also, the enrolled population was heterogeneous, as it included treatment-naive patients, as well as those who did or did not undergo hormonal treatment. Such heterogeneity likely introduced confounding factors into the analysis. The follow-up period was relatively short. In addition, the ideal gold standard for any analysis would be a histological confirmation of obtained findings. On the other hand, clinical follow-up results are considered to be valid for evaluations of diagnostic accuracy and response to therapy, and it would have been unethical to investigate all PET/CT-detected lesions with the use of an invasive procedure. Although the positive findings are easy to confirm, negative findings only indicate that it was not possible to acquire positive findings during a follow-up examination, making it uncertain whether the findings are truly negative. Furthermore, new and more sensitive PET tracers for prostate cancer, such as 18F-FACBC and 68Ga-PSMA, have been recently introduced for clinical use in Western countries [4], though they are not yet available in Japan. One study demonstrated that 68Ga-PSMA PET/CT showed a higher detection rate than 11C-choline PET for lymph nodes as well as bone lesions in patients with prostate cancer [15]. Finally, SPECT/CT findings were not available in the present study. A hybrid imaging method (SPECT/CT) may increase the sensitivity and specificity of bone scintigraphy by identifying benign bone conditions with increases in bone turnover and whenever equivocal findings of planar bone imaging are noted [16].

Conclusions

We found that the lesion-based sensitivity of 11C-choline PET/CT for detection of node and bone metastases in patients with recurrent prostate cancer was significantly higher as compared to the conventional imaging modalities, with results showing equal sensitivity for the diagnosis of local recurrent disease between 11C-choline PET/CT and conventional imaging. 11C-choline-PET/CT is more useful for detecting node and bony metastatic lesions from recurrent prostate cancer than conventional imaging, and has an additional advantage in restaging disease in a single step.


References

  1. Siegel RL, Miller KD, Jemal A: Cancer statistics, 2015. CA Cancer J. 2015, 65:5-29. 10.3322/caac.21254
  2. Kitajima K, Murphy RC, Nathan MA: Choline PET/CT for imaging prostate cancer: an update. Ann Nucl Med. 2013, 27:581-591. 10.1007/s12149-013-0731-7
  3. Kitajima K, Murphy RC, Nathan MA, et al.: Detection of recurrent prostate cancer after radical prostatectomy: comparison of 11C-choline PET/CT with pelvic multiparametric MR imaging with endorectal coil. J Nucl Med. 2014, 55:223-232. 10.2967/jnumed.113.123018
  4. Kitajima K, Yamamoto S, Fukushima K, Minamimoto R, Kamai T, Jadvar H: Update on advances in molecular PET in urological oncology. Jpn J Radiol. 2016, 34:470-485. 10.1007/s11604-016-0553-3
  5. Picchio M, Messa C, Landoni C, et al.: Value of [11C]choline-positron emission tomography for re-staging prostate cancer: a comparison with [18F]fluorodeoxyglucose-positron emission tomography. J Urol. 2003, 169:1337-1340. 10.1097/01.ju.0000056901.95996.43
  6. Beauregard JM, Williams SG, Degrado TR, Roselt P, Hicks RJ: Pilot comparison of F-fluorocholine and F-fluorodeoxyglucose PET/CT with conventional imaging in prostate cancer. J Med Imaging Radiat Oncol. 2010, 54:325-332. 10.1111/j.1754-9485.2010.02178.x
  7. Hara T, Yuasa M: Automated synthesis of [11C]choline, a positron-emitting tracer for tumor imaging. Appl Radiat Isot. 1999, 50:531-553.
  8. Picchio M, Briganti A, Fanti S, et al.: The role of choline positron emission tomography/computed tomography in the management of patients with prostate-specific antigen progression after radical treatment of prostate cancer. Eur Urol. 2011, 59:51-60. 10.1016/j.eururo.2010.09.004
  9. Evangelista L, Zattoni F, Guttilla A, S et al.: Choline PET or PET/CT and biochemical relapse of prostate cancer: a systematic review and meta-analysis. Clin Nucl Med. 2013, 38:305-314. 10.1097/RLU.0b013e3182867f3c
  10. Kitajima K, Hartman RP, Froemming AT, Hagen CE, Takahashi N, Kawashima A: Detection of local recurrence of prostate cancer after radical prostatectomy using endorectal coil MRI at 3 T: Addition of DWI and dynamic contrast enhancement to T2-weighted MRI. AJR Am J Roentgenol. 2015, 205:807-816. 10.2214/AJR.10.5772
  11. Tamada T, Sone T, Jo Y, et al.: Locally recurrent prostate cancer after high-dose-rate brachytherapy: the value of diffusion-weighted imaging, dynamic contrast-enhanced MRI, and T2-weighted imaging in localizing tumors. AJR Am J Roentgenol. 2011, 197:408-414. 10.2214/AJR.10.5772
  12. Scattoni V, Picchio M, Suardi N, et al.: Detection of lymph-node metastases with integrated [11C]choline PET/CT in patients with PSA failure after radical retropubic prostatectomy: results confirmed by open pelvic-retroperitoneal lymphadenectomy. Eur Urol. 2007, 52:423-429. 10.1016/j.eururo.2007.03.032
  13. Shen G, Deng H, Hu S, Jia Z: Comparison of choline-PET/CT, MRI, SPECT, and bone scintigraphy in the diagnosis of bone metastases in patients with prostate cancer: a meta-analysis. Skeletal Radiol. 2014, 43:1503-1513. 10.1007/s00256-014-1903-9
  14. Wieder H, Beer AJ, Holzapfel K, et al.: 11C-choline PET/CT and whole-body MRI including diffusion-weighted imaging for patients with recurrent prostate cancer. Oncotarget. 2017, 8:66516-66527. 10.18632/oncotarget.16227
  15. Schwenck J, Rempp H, Reischl G, et al.: Comparison of 68Ga-labelled PSMA-11 and 11C-choline in the detection of prostate cancer metastases by PET/CT. Eur J Nucl Med Mol Imaging. 2017, 44:92-101. 10.1007/s00259-016-3490-6
  16. Helyar V, Mohan HK, Barwick T, et al.: The added value of multislice SPECT/CT in patients with equivocal bony metastasis from carcinoma of the prostate. Eur J Nucl Med Mol Imaging. 2010, 37:706-713. 10.1007/s00259-009-1334-3
Original article
peer-reviewed

Comparison of 11C-choline Positron Emission Tomography/Computed Tomography (PET/CT) and Conventional Imaging for Detection of Recurrent Prostate Cancer


Author Information

Yusuke Kawanaka

Radiology, Hyogo, Nishinomiya, JPN

Kazuhiro Kitajima Corresponding Author

Radiology, Hyogo College of Medicine, Nishinomiya, JPN

Shingo Yamamoto

Urology, Hyogo College of Medicine, Nishinomiya, JPN

Yukako Nakanishi

Urology, Hyogo College of Medicine, Nishinomiya, JPN

Yusuke Yamada

Urology, Hyogo College of Medicine, Nishinomiya, JPN

Takahiko Hashimoto

Urology, Hyogo College of Medicine, Nishinomiya, JPN

Toru Suzuki

Urology, Hyogo College of Medicine, Nishinomiya, JPN

Shuken Go

Urology, Hyogo College of Medicine, Nisnomiya, JPN

Akihiro Kanematsu

Urology, Hyogo College of Medicine, Nishinomiya, JPN

Michio Nojima

Urology, Hyogo College of Medicine, Nishinomiya, JPN

Keitaro Sofue

Radiology, Kobe University Graduate School of Medicine, Kobe, JPN

Masakatsu Trsurusaki

Radiology, Kinki University Faculty of Medicine, Osakasayama, JPN

Yukihisa Tamaki

Radiation Oncology, Shimane University Faculty of Medicine, Izumo, JPN

Radiation Oncology, Shimane University School of Medicine, Izumo, JPN

Rika Yoshida

Radiology, Shimane University, Faculty of Medicine, Izumo, JPN

Koichiro Yamakado

Radiology, Hyogo College of Medicine, Nishinomiya, JPN


Ethics Statement and Conflict of Interest Disclosures

Human subjects: Consent was obtained by all participants in this study. Hyogo College Hospital issued approval 2019. Hyogo College Hospital issued approval 2019. . Animal subjects: All authors have confirmed that this study did not involve animal subjects or tissue. Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following: Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work. Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work. Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work.